Performance Chart for Venturi Injector 3/4":
Pressure
|
Motive Flow through Ventury injector |
Injection Rate |
| Inlet |
Outlet |
lpm |
lph |
| Kg/cm² |
Kg/cm² |
| 1.00 |
0.0 |
8.5 |
77 |
| 0.2 |
8.4 |
70.8 |
| 0.4 |
8.3 |
47.7 |
| 0.6 |
8.2 |
23.5 |
| 0.8 |
8.2 |
- |
| 1.50 |
0.0 |
10.5 |
73.8 |
| 0.2 |
10.4 |
64.2 |
| 0.4 |
10.4 |
68.1 |
| 0.6 |
10.3 |
50.5 |
| 0.8 |
10.3 |
30.1 |
| 1.0 |
10.3 |
- |
| 2.00 |
0.0 |
12.4 |
70.8 |
| 0.2 |
12.3 |
70.2 |
| 0.4 |
12.2 |
70.0 |
| 0.6 |
12.2 |
64.8 |
| 0.8 |
12.2 |
49.8 |
| 1.0 |
12.2 |
37.3 |
| 1.2 |
12.2 |
30.5 |
| 1.4 |
11.9 |
- |
| 2.50 |
0.0 |
14.0 |
69.3 |
| 0.2 |
13.9 |
68.4 |
| 0.4 |
13.9 |
67.7 |
| 0.6 |
13.8 |
66.1 |
| 0.8 |
13.8 |
60.6 |
| 1.0 |
13.8 |
54.0 |
| 1.2 |
13.8 |
47.1 |
| 1.4 |
13.8 |
30.9 |
| 1.6 |
13.7 |
23.6 |
| 1.8 |
13.7 |
- |
| 3.00 |
0.0 |
15.2 |
68.3 |
| 0.2 |
15.2 |
66.4 |
| 0.4 |
15.2 |
65.2 |
| 0.6 |
15.1 |
65.1 |
| 0.8 |
15.1 |
63.9 |
| 1.0 |
15.1 |
62.4 |
| 1.2 |
15.1 |
58.6 |
| 1.4 |
15.1 |
50.4 |
| 1.6 |
15.0 |
38.0 |
| 1.8 |
15.0 |
26.7 |
| 2.0 |
14.9 |
20.2 |
| 2.2 |
14.9 |
- |
| 3.50 |
0.0 |
16.5 |
128 |
| 0.2 |
16.5 |
128 |
| 0.4 |
16.5 |
97 |
| 0.6 |
16.5 |
97 |
| 0.8 |
16.4 |
95 |
| 1.0 |
16.4 |
90 |
| 1.2 |
16.3 |
84 |
| 1.4 |
16.3 |
84 |
| 1.6 |
16.3 |
84 |
| 1.8 |
16.3 |
67 |
| 2.0 |
16.3 |
48 |
| 2.2 |
16.2 |
22 |
| 2.4 |
16.0 |
- |
| 4.0 |
0.0 |
17.7 |
65.8 |
| 0.2 |
17.7 |
65.0 |
| 0.4 |
17.6 |
64.6 |
| 0.6 |
17.6 |
64.2 |
| 0.8 |
17.5 |
63.8 |
| 1.0 |
17.5 |
64.0 |
| 1.2 |
17.0 |
61.8 |
| 1.4 |
17.5 |
60.9 |
| 1.6 |
17.4 |
57.7 |
| 1.8 |
17.4 |
47.3 |
| 2.0 |
17.4 |
41.7 |
| 2.2 |
17.3 |
40.3 |
| 2.4 |
17.4 |
33.1 |
| 2.6 |
17.3 |
33.1 |
| 2.8 |
17.3 |
- |
Note: Test conducted under standard test conditions with Ventury injector installed on bypass.
Note: For specific pressure difference between inlet and outlet of the injector; if the desired injection rate is more than mentioned in the specifications then the Ventury injector has to be installed in series with a booster pump. |
Performance Chart for Venturi Injector 1" and 1¼":
Pressure
|
Venturi 1" |
Venturi 1¼" |
| Motive Flow |
Injection Rate |
Motive Flow |
Injection Rate |
| Inlet |
Outlet |
lpm |
lph |
lpm |
lph |
| Kg/cm² |
Kg/cm² |
| 1.00 |
0.0 |
59 |
450 |
58 |
790 |
| 0.25 |
59 |
375 |
58 |
750 |
| 0.5 |
55 |
275 |
51 |
400 |
| 1.50 |
0.0 |
67 |
540 |
68 |
800 |
| 0.50 |
67 |
440 |
68 |
750 |
| 0.75 |
62 |
380 |
65 |
700 |
| 1.0 |
62 |
200 |
60 |
150 |
| 2.00 |
0.0 |
75 |
430 |
78 |
750 |
| 0.5 |
75 |
400 |
78 |
700 |
| 0.75 |
75 |
375 |
78 |
680 |
| 1.0 |
75 |
350 |
77 |
650 |
| 1.25 |
72 |
300 |
71 |
420 |
| 1.5 |
70 |
130 |
- |
- |
| 2.50 |
0.0 |
82 |
400 |
87 |
730 |
| 0.5 |
82 |
375 |
87 |
700 |
| 0.75 |
82 |
360 |
87 |
680 |
| 1.0 |
82 |
350 |
87 |
680 |
| 1.25 |
81 |
320 |
87 |
610 |
| 1.5 |
81 |
300 |
81 |
530 |
| 1.75 |
78 |
150 |
79 |
140 |
| 2.0 |
- |
- |
- |
- |
| 3.00 |
0.0 |
88 |
420 |
95 |
730 |
| 1.0 |
88 |
350 |
95 |
720 |
| 1.25 |
88 |
330 |
95 |
700 |
| 1.5 |
88 |
330 |
95 |
680 |
| 1.75 |
88 |
300 |
92 |
450 |
| 2 |
88 |
250 |
89 |
270 |
| 2.25 |
86 |
125 |
88 |
110 |
| 2.5 |
- |
- |
- |
- |
| 3.50 |
0.0 |
95 |
375 |
102 |
670 |
| 1 |
95 |
350 |
102 |
650 |
| 1.5 |
95 |
350 |
102 |
640 |
| 1.75 |
95 |
330 |
102 |
620 |
| 2 |
95 |
300 |
102 |
550 |
| 2.25 |
93 |
250 |
98 |
400 |
| 2.5 |
93 |
220 |
96 |
200 |
| 2.75 |
- |
- |
- |
- |
| 4.0 |
0.0 |
100 |
350 |
118 |
670 |
| 1 |
100 |
350 |
118 |
670 |
| 2 |
100 |
350 |
118 |
650 |
| 2.25 |
100 |
300 |
118 |
610 |
| 2.5 |
100 |
280 |
118 |
600 |
| 2.75 |
100 |
250 |
114 |
390 |
| 3 |
98 |
130 |
113 |
200 |
| 3.25 |
- |
- |
- |
- |